Seismic Design in ProtaStructure 2019 Webinar

Seismic Design in ProtaStructure 2019

Content:
  1. Specification of Seismic Parameters
  2. Calculation of Mass • Eigenvalue Analysis
  3. Equivalent Static Load Method
  4. Mode-Superposition Method
  5. Two-stage Analysis
  6. Building Base and Height Check
  7. Stiffness Modifiers
  8. Vertical Earthquake Effects
  9. Horizontal and Vertical Irregularities
  10. Selection of Analysis Method
  11. Relative Storey Drift Check
  12. Second-Order Requirements Check
  13. Seismic Overturning Check
  14. Strong Column – Weak Beam Check
  15. Joint Shear Check
  16. Ductile Member Design and Detailing
  17. Diaphragm Models and Storey MEshing
  18. Shearwall Modelling and Basement Walls
  19. Wall Coupling Beams
  20. Seismic Isolators
  21. Assessment and Retrofit of Existing Buildings
  22.  Nonlinear Pushover and Time History Analyses with OpenSees Integration

Host: Mustafa T. TAN, Product Manager, Prota Software


    • Related Articles

    • Effective Stiffness Modifiers

      In ProtaStructure, effective stiffness modifiers of the slabs could be adjusted for different analysis methods. One of the method is using the “Finite Elements Floor Analysis” option independent from the building under vertical load cases only. This ...
    • Beam-Column Joint Shear Design and Strong Column Weak Beam Checks

      For 2021 and prior versions, Beam-Column Joint Shear Design and Strong Column Weak Beam condition checks were given in the same report which is Post-Analysis Design Checks Report. With ProtaStructure 2025, Beam Column Joint Shear Design and Strong ...
    • Seismic Analysis to Indonesia SNI 1726 : 2019

      ProtaStructure can now calculate seismic loads in accordance with Indonesia (SNI 1726 :2019 ) seismic code, which is an adaptation of ASCE07. After selecting the Earthquake Code via Parameter in Building Analysis dialog > Pre-analysis tab, pick ...
    • Seismic Analysis to Philippines NSCP2015

      ProtaStructure can now calculate seismic loads in accordance with Philippines (NSCP2015) seismic code, which is an adaptation of UBC97. After selecting the Earthquake Code via Parameter in Building Analysis dialog > Pre-analysis tab, pick Seismic ...
    • Seismic Separation Design according to ASCE7-16

      ProtaStructure determines the seismic separation condition according to ASCE 7-16 Clause 12.12.3. In this document, calculation details about seismic separation conditions are explained. We present this design guide to your attention with the hope ...