Pre-Analysis
Seismic Analysis to India IS 1893-2016
ProtaStructure can calculate seismic loads in accordance with India (IS 1893-2016) seismic code, which covers the key parts of IS codes. Firstly ensure that required seismic code is selected. Refer to this article : Seismic Load - Basic Guide Go to ...
Wind and Storey Loads
Lateral loads can be applied at each floor level of the analysis model, or individual Column/Wall nodes (Joint loads that can be assigned to individual columns/walls are not limited only to lateral loads). You can use the “Wind and Storey Load” to ...
Material
Pre-Analysis Tab Concrete and steel grades are assigned to each member type from the “ Pre-Analysis ” tab page in the “ Building Analysis ” Form. Unit Weight of Member Unit Weight of Concrete given in this field is used for calculating the ...
Notional Load and Input
Create Notional Load Cases and Combination To add Notional Load to the model, the Notional Load Cases and Load Combinations shall be generated: Analysis > Building Analysis > Pre-Analysis > Loading Combinations> Loading Generator > Horizontal Load ...
Seismic Analysis to Indonesia SNI 1726 : 2019
ProtaStructure can now calculate seismic loads in accordance with Indonesia (SNI 1726 :2019 ) seismic code, which is an adaptation of ASCE07. After selecting the Earthquake Code via Parameter in Building Analysis dialog > Pre-analysis tab, pick ...
Seismic Analysis to EuroCode 8
ProtaStructure can calculate seismic loads in accordance EuroCode 8. Country specific requirements of the following National Annex have been implemented : MS EN 1998-1 : 2015 (Malaysia National Annex) SS EN 1998-1 : 2013 (Singapore National Annex) ...
Seismic Load - Basic Guide
General You will learn how to incorporate the basic seismic loading into your model. You will know how to view & check the seismic mode shapes It is very important that the user to refer the relevant earthquake code for detail explanations of the ...
Seismic Analysis to Philippines NSCP2015
ProtaStructure can now calculate seismic loads in accordance with Philippines (NSCP2015) seismic code, which is an adaptation of UBC97. After selecting the Earthquake Code via Parameter in Building Analysis dialog > Pre-analysis tab, pick Seismic ...
Wind and Storey Loads
Lateral loads can be applied at each floor level of the analysis model, or individual Column/Wall nodes (Joint loads that can be assigned to individual columns/walls are not limited only to lateral loads). You can use the “Wind and Storey Load” to ...
Load Combinations
The load combinations to be used during the analysis of the building model can be specified by clicking the "Load Combinations" button which is located on the Pre-Analysis tab of the Building Analysis form. The figure below shows the Load Combination ...
Pre-Analysis Overview
Before analysing the building you must ensure that Project Parameters, Load Combinations, Wind & Storey Loads and Materials have been correctly defined. These settings are all located on the Pre-Analysis tab of the “Building Analysis” dialog. They ...